Voltage temperature drift, Voltage stability, Voltage load regulation – AMETEK ReFlex User Manual

Page 211: Voltage line regulation, Voltage load transient, Voltage line transient, Remote sense capability

Advertising
background image

DC Power Supplies

ReFlex Power™

6-8

M380056-01 Rev K

V

OLTAGE

T

EMPERATURE

D

RIFT

0.01% of full-scale/°C, maximum

V

OLTAGE

S

TABILITY

0.05% of full-scale after 24 hours at constant line, load, and temperature
1.0% of full-scale after 2000 hours at constant line, load, and temperature

V

OLTAGE

L

OAD

R

EGULATION

RFP-D1016-021-XXXX, RFP-D1065-5A1-XXXX:

less than 0.01% of full-scale plus 10 mV for 100% load change

RFP-D2033-030-XXXX, RFP-D2050-020-XXXX, RFP-D2050-025-XXXX,
RFP-D2120-8A3-XXXX, RFP-D2450-2A3-XXXX:

less than 0.03% of full-scale plus 10 mV for 100% load change

V

OLTAGE

L

INE

R

EGULATION

RFP-D1016-021-XXXX, RFP-D1065-5A1-XXXX:

less than 0.01% of full-scale plus 10 mV for a 10% line change

RFP-D2033-030-XXXX, RFP-D2050-020-XXXX, RFP-D2050-025-XXXX,
RFP-D2120-8A3-XXXX, RFP-D2450-2A3-XXXX:

less than 0.03% of full-scale plus 10 mV for a 10% line change

V

OLTAGE

L

OAD TRANSIENT

Less than 5% of full-scale excursion returning to the steady-state value, within
0.5% of full-scale, in 2 ms maximum, and within DC regulation limits after 10
ms for 10, 50, and 90% load step above and below 50% load.

V

OLTAGE

L

INE TRANSIENT

Less than 1% of full-scale excursion returning to steady-state value, within
0.1% of full-scale, in 0.5ms maximum for 10% line change

R

EMOTE

S

ENSE

C

APABILITY

•

Remote sense compensates for at least 1.5V per load line connection.

•

Maximum output power rating is valid at module output terminals,
since line drop subtracts from maximum load voltage.

•

Neither the module nor the load would be damaged by opening the
sense leads during operation; module will continue to maintain output,
but with reduced programming accuracy to 5%, maximum.

•

Misconnection of the sense leads would not result in an output voltage
in excess of the over-voltage protection limit.

•

Output Shutdown would occur if any of the following happen:

•

Sense leads connected with reversed polarity

•

Sense leads short-circuited

•

Excessive load line voltage drop

Advertising