4 new configuration of ax2000/2500, New configuration, New configuration of ax2000/2500 – BECKHOFF AX2000 CANopen communication profile User Manual

Page 135: Appendix

Advertising
background image

Index

Sub-

index

DEF

Data format

Access

PDO

mapp.

Description

ASCII Object

607C

h

00

h

4

INTEGER32

rww

ý

Reference offset

—

6081

h

00

h

4

UNSIGNED32

rww

ý

Velocity (Mode: pp)

—

6083

h

00

h

4

UNSIGNED32

rww

ý

Acceleration (Mode: pp pv)

—

6084

h

00

h

4

UNSIGNED32

rww

ý

Deceleration (Mode: pp pv)

—

6086

h

00

h

4

INTEGER16

rww

ý

Type of motion block ramp (motion_profile_type)

—

6089

h

00

h

4

INTEGER8

rw

—

Notation index: position (not supported)

—

608A

h

00

h

4

UNSIGNED8

rw

—

Dimension index: position (not supported)

—

608B

h

00

h

4

INTEGER8

rw

—

Notation index: speed (not supported)

—

608C

h

00

h

4

UNSIGNED8

rw

—

Dimension index: speed (not supported)

—

608D

h

00

h

4

INTEGER8

rw

—

Notation index: acceleration (not supported)

—

608E

h

00

h

4

UNSIGNED8

rw

—

Dimension index: acceleration (not supported)

—

6093

h

00

h

4

UNSIGNED32

rw

—

Position factor

—

01

h

4

UNSIGNED32

rww

ý

Numerator

PGEARO

02

h

4

UNSIGNED32

rww

ý

feed_constant

PGEARI

6094

h

00

h

4

UNSIGNED32

rw

—

Velocity factor: encoder

—

01

h

4

UNSIGNED32

rw

—

Numerator

—

02

h

4

UNSIGNED32

rw

—

Divisor

—

6097

h

00

h

4

UNSIGNED32

rw

—

Acceleration factor

—

01

h

4

UNSIGNED32

rw

—

Divisor

—

02

h

4

UNSIGNED32

rw

—

Acceleration factor

—

6098

h

00

h

4

INTEGER8

rww

ý

Homing type

—

6099

h

00

h

4

ARRAY

ro

—

Homing velocity

—

01

h

4

INTEGER32

rw

ý

Homing velocity
(homing to references switch)

VREF

02

h

4

INTEGER32

ro

ý

Homing velocity (homing to resolver zero mark)

VREF

609A

h

00

h

4

UNSIGNED32

rw

ý

Homing acceleration

—

60C2

h

00

h

4

RECORD

ro

—

Interpolation time period

PTBASE

01

h

4

UNSIGNED8

rw

—

Interpolation time units

—

02

h

4

INTEGER16

rw

—

Interpolation time index

—

60FF

h

00

h

4

INTEGER32

rw

ý

Speed setpoint

—

6.4

New configuration of AX2000/2500

In AX2000/2500 there are a number of parameters, that can only be integrated into the current firm-
ware program and produce their proper effect for the first time during the initialization phase, when
the amplifier is switched on. As a result, an alteration of one of these parameters means that all
parameters have to be saved, and the amplifier must then be restarted. This can be carried out via
the CAN-bus, by using the following Objects:

1. Write Object 35EB

h

Sub-index 01

h

, value 0, save command

2. Write Object 3632

h

Sub-index 01

h

, value 0, restart amplifier

CANopen for AX2000/2500

135

BECKHOFF

07/2007

Appendix

Advertising