Sub-index

12

h

Brief description

position absolut encoder in SI units

Unit

user units

Access

ro

PDO mapping

possible

Data type

INTEGER32

Value range

-(2

31

-1)..(2

31

-1)

Default value

Assuming that an absolute encoder has been configured in the device (EXTPOS 1, 2 or 3), this
Object can be used to determine the encoder position. Scaling is defined by parameters PGEARI,
PGEARO, ENCIN, and EXTMUL.

Sub-index

13

h

Brief description

Internal Position Setpoint

Unit

internal position counts

Access

ro

PDO mapping

possible

Data type

INTEGER32

Value range

-(2

31

-1)..(2

31

-1)

Default value

This Object can be used to read the position setpoint used for internal position control. The value is
output in internal position counts.

Sub-index

14

h

Brief description

Analog Input 1 actual value

Unit

mV (scaled)

Access

ro

PDO mapping

possible

Data type

INTEGER16

Value range

-(2

15

-1)..(2

15

-1)

Default value

This Object supplies a scaled value for the input voltage at analog input 1. In this context, 10 V cor-
responds to 8192 increments.

Sub-index

15

h

Brief description

Analog Input 2 actual value

Unit

mV (scaled)

Access

ro

PDO mapping

possible

Data type

INTEGER16

Value range

-(2

15

-1)..(2

15

-1)

Default value

This Object supplies a scaled value for the input voltage at analog input 2. In this context, 10 V cor-
responds to 8192 increments.

84

CANopen for AX2000/2500

CANopen Drive Profile