Sub-index

17

h

Brief description

internal velocity setpoint

Unit

Access

ro

PDO mapping

possible

Data type

INTEGER32

Value range

-(2

31

-1)..(2

31

-1)

Default value

This Object can be used to read out the internal speed setpoint. In this context, an internal speed
count corresponds to a position count/250 microseconds. Thus, the speed in rpm is calculated as
follows:

v

v

rpm

incr

=

×

×

4000

2

60

20

Sub-index

18

h

Brief description

Master velocity (electronic gear)

Unit

Access

ro

PDO mapping

possible

Data type

UNSIGNED32

Value range

0..(2

32

-1)

Default value

This Object supplies the speed resulting from the master-encoder pulses read in on the electronic
gear (Mode 0xF7).

Sub-index

19

h

Brief description

control variable (electronic gear)

Unit

Access

ro

PDO mapping

possible

Data type

INTEGER8

Value range

-(2

7

-1)..(2

7

-1)

Default value

0

This Object is used to display the status/transition associated with synchronization/decoupling within
the electronic gear. The following values are defined (only when ENGAGE = 1 or 3):

Value

Description

0

No synchronization

1

Synchronization with master speed using ramp ACCR

2

Uncoupling using ramp DECR

3

Travel synchronized with master

4

Synchronization over distance defined by Object 2050 sub 5