Sub-index

09

h

Brief description

resolution / numerator of the gearing ratio

Unit

μm

Access

rw

PDO mapping

not possible

Data type

UNSIGNED32

Value range

1 ... (2

32

-1)

Default value

1

The ratio of the values of Sub-indices 08

h

and 09

h

provides the mechanical resolution of the axis in

μm/turn.

Sub-index

0A

h

Brief description

count direction

Unit

Access

rw

PDO mapping

not possible

Data type

UNSIGNED8

Value range

0, 1

Default value

1

The value gives the count direction for current, speed, and position control. A value of 1 means that
the positive count direction has been selected. If a positive setpoint is provided, the motor shaft
rotates in a clockwise direction (looking at the shaft end).