4.12

Freely available, mappable PLC variables, Objects 2030h / 2090h

Parameters DPRVAR1 .. DPRVAR16 enable status variables to be exchanged between the CAN
bus and internal PLC sequential program. Two sets of eight Objects - one for write-only (WO) and
one for read-only - are provided for this purpose (these Objects can also be mapped in PDOs).

4.12.1

Object 2030h: DP-Ram-Variables 9-16 (write only)

Index

2030

h

Brief description

DP-Ram Variables, write only (PDO)

Object code

ARRAY

Number of elements

9

Sub-Indexes:

Sub-index

01

h

...08h

Brief description

DP-Ram Variable 9...16

Unit

Access

rw

PDO mapping

possible

Data type

INTEGER32

Value range

INTEGER32

Default value

0

4.12.2

Object 2090h: DP-Ram-Variables 1-8 (read only)

Index

2090

h

Brief description

DP-Ram Variablen, nur lesbar (PDO)

Object code

ARRAY

Number of elements

9

Sub-Indexes:

Sub-index

01

h

...08h

Brief description

DP-Ram Variable 1...8

Unit

Access

ro

PDO mapping

possible

Data type

INTEGER32

Value range

INTEGER32

Default value

0