2 object description, 1 object 6040h: controlword (ds402), 6040h – BECKHOFF AX2000 CANopen communication profile User Manual

Page 53: Control word, Object description, Object 6040h: controlword (ds402), Canopen drive profile

Advertising
background image

4.4.2

Object description

4.4.2.1

Object 6040h: Controlword (DS402)

The control commands are built up from the logical combination of the bits in the control word and
external signals (e.g enable output stage). The definitions of the bits are shown below:

Index

0x6040

h

Name

control word

Object code

VAR

Data type

UNSIGNED16

Mode

all

Access

rw

PDO mapping

possible

Unit

Value range

0 ... 65535

EEPROM

no

Default value

0

Bit assignment im control word

Bit Name

Bit Name

0

Switch on

8

Pause/halt

1

Disable Voltage

9

reserved

2

Quick Stop

10 reserved

3

Enable Operation

11

Acknowledge lag/following error and response
monitoring

4

Operation mode specific

12 Reset position

5

Operation mode specific

13 Manufacturer-specific

6

Operation mode specific

14 Manufacturer-specific

7

Reset Fault (only effective for faults)

15

Manufacturer-specific

Commands in the control word

Command

Bit 7

Fault Reset

Bit 3

Enable

Operation

Bit 2

Quick Stop

Bit 1

Disable
Voltage

Bit 0

Switch on

Transitions

Shutdown

X

X

1

1

0

2, 6, 8

Switch on

X

X

1

1

1

3

Disable Voltage

X

X

X

0

X

7, 9, 10, 12

Quick Stop

X

X

0

1

X

7, 10, 11

Disable Operation

X

0

1

1

1

5

Enable Operation

X

1

1

1

1

4, 16

Fault Reset

1

X

X

X

X

15

Bits marked by an X are irrelevant.

CANopen for AX2000/2500

53

BECKHOFF

07/2007

CANopen Drive Profile

Advertising