5 object 6097h: acceleration_factor (ds402), 6097h, Object 6097h: acceleration_factor (ds402) – BECKHOFF AX2000 CANopen communication profile User Manual

Page 62: Beckhoff

Advertising
background image

4.5.2.5

Object 6097h: acceleration_factor (DS402)

The acceleration_factor converts the acceleration [unit: /s

2

] into the internal format of the

AX2000/2500.
At present, the numerator and divisor are read-only. The values are set to 1. If the acceleration_fac-
tor
is 1, then the ramp settings (Object 6083

h

profile_acceleration and Object 6084

h

profile_deceler-

ation) will be provided as acceleration times [ms] required to reach the target speed (Object 6081

h

profile_velocity).

Index

0x6097

h

Name

acceleration_factor

Object code

ARRAY

Number of elements

2

Data type

UNSIGNED32

Sub-Indexes:

Sub-index

01

h

Brief description

numerator

Mode

pp, pv

Access

ro

PDO mapping

not possible

Unit

increments [incr]

Value range

0 ... (2

32

-1)

EEPROM

no

Default value

0

Sub-index

02

h

Brief description

divisor

Mode

pp, pv

Access

ro

PDO mapping

not possible

Unit

Value range

0 ... (2

32

-1)

EEPROM

no

Default value

0