Port, Format – Wavetronix SmartSensor HD (101-0415) - User Guide User Manual

Page 76

Advertising
background image

CHAPTER 7 • DATA

75

Figure 7.10 – Data Push

To enable data push, select the Event, Interval or Presence tab, then select which method

of communication and format you are using and turn the function on by checking the En-

abled checkbox.

Port

This allows you to select the SmartSensor HD communications port through which the

data will be pushed. If the sensor is pushing data on a half-duplex communication port, the

sensor may not respond to commands due to collisions on the communications bus.

Note

SmartSensor HD's native RS-232 and RS-485 ports are both half duplex.

Format

The following formats are available for all three data types:

˽

HD Format – This outputs the data in the native SS125 format (see the SmartSensor HD

Released Communications Protocols document for information on this format).

˽

SS105 Simple Format – This outputs the data in the SSHD SS105 emulation format

without a multi-drop header (see the SmartSensor HD Released Communications Pro-

tocols document for information on this format).

˽

SS105 Multidrop Format – This outputs the data in the SSHD SS105 emulation format

with a multi-drop header (see the SmartSensor HD Released Communications Protocols

document for information on this format).

For Event Data, there are five additional format options. All of them output the data in Z4

format. Z4 is a Wavetronix-specific protocol that allows sensors to talk to other Wavetronix

Advertising