44 CyberSWITCH

To clean the air filter:

1.

Power down the system and disconnect the system’s power cord from the power source.

2.

Open the door located on the right side of the front chassis.

3.

Once the door is opened, you can slide the air filter out from the left side of the chassis.

4.

Once removed, clean the filter by washing it in warm water and a mild detergent. Make sure it
is completely dry before you place it back in the system.

5.

Slide the filter back into place.

6.

Close the chassis door.

7.

Reconnect the power cord and power up the system.

P

LATFORM

C

HARACTERISTICS

Physical Characteristics

Height:

171.5 mm (6.86 in)

Width:

430 mm (17.2 in)

Depth:

483 mm (19.32 in)

Weight:

18 kg maximum (40 lb. maximum)

Environmental Characteristics

Operating Temp:

0

°

to 55

°

C (32

°

to 131

°

F)

Operating Humidity:

5 to 95% non-condensing

Operating Altitude:

3048 m maximum (10,000 ft maximum)

Non-operating Shock:

40 G, 11 ms 1/2 sine wave

Storage Temperature:

0

°

to 70

°

C (32

°

to 158

°

F)

Electrical AC Power Input

Voltage:

90 - 120 V

Current:5 A

Voltage:

180 - 265 V

Current:4 A

Frequency:

47 - 63 Hz

Regulatory Compliance

Meets or exceeds the following:
Safety:

UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950,
and 72/23/EEC

EMI:

FCC Part 15, EN 55022, CSA 108.8, EN 50082-1,
VCCI V-3, and 89/336/EEC

Rack Mounting:

475 mm (19 inch) Industrial Rack Mount Chassis meets EIA RS-310C standard