Rs232 adapter, Rs232 adapter 65 – Enterasys Networks CSX6000 User Manual

Page 65

Advertising
background image

Central Site Remote Access Switch 65

H

ARDWARE

O

VERVIEW

System Adapters

Pin and Signal Assignments for the V.35 Connection

RS232 A

DAPTER

The RS232 adapter provides four RS232 ports. The card contains two female DB26 connectors. An
RS232 adapter cable converts the DB26 connection to two standard RS232 connections. Using the
RS232 adapter cable, DB26 port # 1 becomes RS232 port # 1A and port # 1B. You can configure each
port pair (1A,1B or 2A,2B) for DTE (external clocking) or DCE (internal clocking), and each port
supports data rates from 2.4 Kbps to 56 Kbps.

The RS232 supports network side connections, providing dedicated connections to other systems.
The adapter can take advantage of slower speed analog lines by using standard synchronous
analog modems. The RS232 also supports private network connections through a T1 multiplexer or
a channel bank.

V.35 Pin

Signal

Function

V.35 Pin

Signal

Function

A

Chass

ChassisGround

V

RXCB

Receive Clock B

B

Gnd

Signal Return

W

NC

No Connect

C

RTS

Request to Send

X

RXCA

Receive Clock

D

CTS

Clear to Send

Y

TXCB

Transmit Clock B

E

DSR

Data Set Ready

Z

NC

No Connect

F

DCD

Data Carrier

Detect

AA

TXCA

Transmit Clock

A

H

DTR

Data Terminal

Ready

BB

NC

No Connect

J

RI

Ring Indicator

CC

NC

No Connect

K

LT

Local Test

DD

NC

No Connect

L

NC

No Connect

EE

NC

No Connect

M

NC

No Connect

FF

NC

No Connect

N

NC

No Connect

HH

NC

No Connect

P

TDB

Transmit Data B

JJ

NC

No Connect

R

RDB

Receive Data B

KK

NC

No Connect

S

TDA

Transmit Data A

LL

NC

No Connect

T

RDA

Receive Data A

MM

NC

No Connect

U

NC

No Connect

NN

NC

No Connect

Advertising