Installation and configuration, Usage instructions – Enterasys Networks CSX6000 User Manual

Page 564

Advertising
background image

USER’S GUIDE

564 CyberSWITCH

on the same subnetwork as the Telnet client on System 1’s LAN, a static route is needed to allow
System 2 to communicate with devices on Network 1. Because the CyberSWITCH had no Telnet
client capabilities in previous releases, the only way to fix the problem was to physically go to the
remote site and add a static route.

The second example network shown illustrates the current CyberSWITCH release. System 1 has
Telnet client capabilities, and therefore can simply Telnet to System 2 and add the needed static
route.

I

NSTALLATION

AND

C

ONFIGURATION

Telnet is available by default when IP routing is enabled. No installation or configuration steps are
required.

U

SAGE

I

NSTRUCTIONS

To access the CyberSWITCH using Telnet, you must have a Telnet client software package. A
Telnet client software package is built into the CyberSWITCH. With the CyberSWITCH acting as
the Telnet client, simply enter the

telnet <ip address>

command to Telnet into the target

host. Refer to the System Commands chapter for a complete listing of available

Telnet commands

.

If you are using a PC or a workstation as a Telnet client, it must have a Telnet client software
package. From the Telnet client package, issue the command that will allow you to connect to the

Telnet Client

(Sub) Network 1

(Sub) Network 2

(Sub) Network 3

No route entry
configured to
Network 1

"SITE2"

"SITE1"

X

Can not communicate

"SITE1"

"SITE2"

Telnet Client

(Sub) Network 1

(Sub) Network 2

(Sub) Network 3

No route entry
configured to
Network 1

Can fix configuration problem
in SITE2 remotely
through SITE1

Remote Site

Remote Site

Telnet Client

CURRENT RELEASE:

EARLIER RELEASES:

ISDN

ISDN

CSX5500

CSX5500

CSX5500

CSX5500

Advertising