Central Site Remote Access Switch 57

H

ARDWARE

O

VERVIEW

System Platforms

6.

Insert the clean and dry air filter back into its slot behind the chassis front. Tilt the filter forward
into place until it is flush against the chassis front panel.

7.

Reinstall the two retaining screws along the top lip of the chassis.

8.

Replace the system’s top cover.

9.

Reconnect the power cord and power up the system.

P

LATFORM

C

HARACTERISTICS

Physical Characteristics

Height:

178 mm (7.0 in)

Width:

432 mm (17.0 in)

Depth:

452 mm (17.8 in)

Weight:

22 kg maximum (44 lb. maximum)

Environmental Characteristics

Operating Temp:

0

°

to 50

°

C (41

°

to 122

°

F)

Operating Humidity:

20 - 85% non-condensing

Operating Altitude:

3048 m maximum (10,000 ft maximum)

Non-operating Shock:

40 G, 11 ms 1/2 sine wave

Storage Temperature:

-25

°

to +70

°

C (-13

°

to 158

°

F)

Electrical AC Power Input

Voltage:

90 - 135 V

Current:5 A

Voltage:

180 - 265 V

Current:4 A

Frequency:

47 - 63 Hz

Regulatory Compliance

Meets or exceeds the following:
Safety:

UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950,
and 72/23/EEC

EMI:

FCC Part 15, EN 55022, CSA 108.8, EN 50082-1,
VCCI V-3, and 89/336/EEC

Advertising