124

VS-616G5 Programming Manual

Section L: Operator Parameters

O2 Key Selections

If the digital operator is disconnected from the inverter, this parameter selects whether the inverter
detects this condition.

This function can only be activated when the run command comes from the digital operator.

Setting Range:

0 to 65535 Hours

Factory Default:

0 Hours

Sets the initial value for the cumulative operation time. Operation time starts accumulating from the set
value. This is very useful for preventive maintenance purposes.

Defines the operation time that accumulates in the timer.

Sets factory defaults to worldwide specifications.

After changing this setting, reinitialize the inverter in parameter A1-03. This initialization affects mar-
ket-driven parameter settings (motor-related parameters, carrier frequency, inverter rated current, etc.)

O2-06 Digital Operator Disconnection Detection

Oper Detection

A

A

A

A

Setting

Description

0

Detection is disabled. Operation continues (factory default).

1

Detection is enabled. When the inverter detects that the digital operator has been discon-

nected while running, the inverter coasts to stop and the error message “OPR Operator

Disconnected” is displayed on the digital operator, after it is connected again.

O2-07 Operation Time Setting

Elapsed Time Set

A

A

A

A

O2-08 Cumulative Operation Time Selection

Elapsed Time Run

A

A

A

A

Setting

Description

0

Power-On time is the accumulated time (factory default).

The timer counts the time while the inverter power supply is turned ON as operation time.

1

Running time is the accumulated time. The timer counts the time while the inverter is running

as operation time.

O2-09 Initialization Mode Selection

Init Mode Sel

A

A

A

A

Setting

Description

0

Japanese specifications

1

American specifications (factory default)

2

European specifications

3

OMRON specifications