Yaskawa VS-616G5 Series Revision F Programming Manual User Manual

Page 75

Advertising
background image

VS-616G5 Programming Manual

75

V/f

V/f w/PG Open Loop

Vector

Flux

Vector

The setting of parameter F9-03 selects the stopping method when an EF0 fault is detected.

Setting Range:

0-60000

Factory Default:

0

Parameter F9-04 sets the trace sample time when using the CP-916B option card.

Parameter F9-05 allows the CP-916 option card to set the torque limits when the inverter is in the
speed control mode and the torque reference when operating in the torque control mode

Operation Truth Table for Parameter F9-05

Note: The inverter will use the lowest value from the CP-916, L7-01 to L7-04, or the multi-function

analog input terminals 14 or 16.

F9-03 Option External Fault Action

EFO Fault Action

A

A

A

A

Setting

Description

0

Ramp to stop according to C1-02 set value.

1

Coast to stop. (factory setting)

2

Ramp to stop according to C1-09 set value.

3

Alarm flashes, operation continues.

F9-04 Trace Sample Time

Trace Sample Tim

A

A

A

A

F9-05 Torque Reference/Torque Limit Select (CP-916)

Torq Ref/Lmt Sel

-

-

-

A

Setting

Description

0

Disabled -Torque reference/torque limits set by G5 pro-
gram parameters or by analog input.

1

Enabled - Torque reference/torque limits set by G5 pro-
gram parameters, analog input, or by the CP-916. (factory
default)

Set Value

Speed Control (Torque Limit)

Torque Control (Torque Reference)

F9-05 = 0 Set by parameter or analog input.

Set by analog input terminal 14 or 16.

F9-05 = 1 Set by CP-916 option card, parameter, or analog

input.

Set by CP-916 option card.

Section F: Option Parameters

F9 CP-916 Option Set-up