Main menu: auto-tuning – Yaskawa VS-616G5 Series Revision F Programming Manual User Manual

Page 125

Advertising
background image

VS-616G5 Programming Manual

125

Main Menu: Auto-Tuning

<ENTER>

Adaptation to most all 3 phase induction motors manufactured worldwide is possible with the VS-
616G5’s automatic tuning function. Available in both open loop vector and flux vector control modes,
the inverter asks the user for minimal motor information, then guides the user through a quick, simple
tuning process. Below is the motor data required for automatic tuning in the quick-start mode:

After scrolling through tuning parameters using the

key, depress the Run key to begin auto-tuning.

During tuning, “Tune Proceeding” flashes on the digital operator display. After complete, “Tune Suc-
cessful” is displayed.

Note:

If the Stop key is depressed during tuning, auto-tuning is interrupted and the motor coasts to
stop. The data changed during tuning returns to its original values.

After tuning is complete, depress the Menu key to exit the auto-tuning mode.

Motor Rated Voltage

Sets motor rated voltage in VAC.

Q

Q

Motor Rated Current

Sets motor rated current in A.

Q

Q

Motor Rated Frequency

Sets motor rated frequency in Hz.

Q

Q

Motor Rated Speed

Sets motor rated speed in rpm.

Q

Q

Number of Motor Poles

Sets the number of motor poles.

Q

Q

Motor Selection

Chooses connected motor as 1st or 2nd motor.

Q

Q

Section: Auto-Tuning

Auto-Tuning Procedure

Advertising