VS-616G5 Installation & Quick-Start Manual

99

Group

H T

ermi

nal

F

unc

tion

Fu

nc

tion

H4 Anal

og Outp

uts

H4-01

Monitor Selection
Terminal 21
(Terminal 21 Sel)

1~38

1

2

Analog output selection (terminal

21 (same as F4-01)

1: Frequency reference

2: Output frequency

3: Inverter output current

5: Motor speed

6: Output voltage

7: DC bus voltage

8: Output power

9: Torque reference (internal)

15: External terminal 13 input

voltage

16: External terminal 14 input

voltage

17: External terminal 16 input

voltage

18: Motor secondary current (Iq)

19: Motor excitation current (Id)

20: Primary frequency after SFS

21: Speed controller ASR input

22: Speed controller ASR output

23: Speed deviation

24: PID feedback

26: Voltage reference (Vq out-

put)

27: Voltage reference (Vd out-

put)

31: Not Used

32: ACR (q) Output

33: ACR (d) Output

36: PID Input

<1110>

37: PID Output

<1110>

38: PID Reference

<1110>

x

B

B

B

B

H4-02

Terminal 21 Output
Gain
(Terminal 21 Gain)

0.00~

2.50

0.01

1.00

o

B

B

B

B

H4-03

Terminal 21Output
Bias
(Terminal 21 Bias)

–10.0~

+10.0

0.0%

0.0

o

B

B

B

B

H4-04

Terminal 23
Monitor
(Terminal 23 Sel)

1~38

1

3

Analog output selection (terminal

23) (same as H4-01)

x

B

B

B

B

H4-05

Terminal 23 Output
Gain
(Terminal 23 Gain)

0.00~

2.50

0.01

0.50

o

B

B

B

B

H4-06

Terminal 23 Output
Bias
(Terminal 23 Bias)

–10.0~

+10.0

0.1%

0.0

o

B

B

B

B

H4-07

Analog Output
Signal Selection
(AO Level Select)

0, 1

1

0

0: (0 - +10 VDC)
1: (–10V +10 VDC)

x

B

B

B

B

Function

Parameter

No.

Name

(Digital Operator

Display)

Setting

Range

Setting

Unit

Factory

Setting

Remarks

(Digital Operator Display)

Change

during

Operation

o: Enabled

x: Disabled

Parameter Access Level

User

Setting

V/f

V/f

w/

PG

Open

Loop

Vector

Flux

Vector

Appendix

VS-616G5 Parameters