Yaskawa VS-616G5 Series Revision F Quick-Start User Manual

Page 54

Advertising
background image

VS-616G5 Installation & Quick-Start Manual

51

Setting Range:

0.00 to 6000.0s

Factory Default:

10.0s

Acceleration time 1 sets the time necessary for the output frequency to accelerate from 0Hz to maxi-
mum output frequency as set in parameter E1-04. Deceleration time 1 sets the time necessary for the
output frequency to decelerate from the maximum output frequency to 0Hz.

Setting Range:

0.0 to 400.0Hz

Factory Default:

0.0Hz

Up to 4 preset speed references (including jog) can be set through multi-function contact input func-
tion selections in the Quick-Start mode. Terminals 6 and 7 are factory defaulted to multi-step speed
inputs 1 and 2, respectively. See the following table for programming preset speed references in the
Quick-Start mode.

Note: 9 preset references can be set in the Advanced modes.

The jog frequency reference can be set in this parameter. In the Quick-Start mode, depress the
JOG key on the digital operator, or close terminal 7 when parameter H1-05 is set to “6”, to use
this function. The jog command always has priority over other reference commands. When
using terminal 7 to select the jog frequency, a separate run command must be applied to run
the inverter.

V/f

Control

V/f

w/ PG

Open Loop

Vector

Flux

Vector

C1-01 Acceleration time 1

Accel Time 1

C1-02 Deceleration time 1

Decel Time 1

V/f

Control

V/f

w/ PG

Open Loop

Vector

Flux

Vector

D1-01 Preset Frequency Reference 1

Reference 1

D1-02 Preset Frequency Reference 2

Reference 2

D1-03 Preset Frequency Reference 3

Reference 3

D1-04 Preset Frequency Reference 4

Reference 4

Terminal 5

Terminal 6

Speed Reference

Open

Open

Speed Reference 1 - Set Reference Source (B1-01) to “0”.

Closed

Open

Speed Reference 2 (When H3-05

≠ 0 and H3-09 ≠ 0)

Open

Closed

Speed Reference 3

Closed

Closed

Speed Reference 4

V/f

Control

V/f

w/ PG

Open Loop

Vector

Flux

Vector

D1-09 Jog Frequency Reference

JOG Reference

Chapter 3 - Quick-Start Programming

Programming Menu

Advertising