Yaskawa VS-616G5 Series Revision F Quick-Start User Manual

Page 81

Advertising
background image

78

VS-616G5 Installation & Quick-Start Manual

Gro

up b Appl

ic

at

io

n

Func

tion b2 D

C

Inj

ec

tion Bra

ke

B2-01

DC Injection
Braking Starting
Frequency
(DCInj Start Freq)

0.0~
10.0

0.1Hz

0.5

x

B

B

B

B

B2-02

DC Injection
Current
(DCInj Current)

0~100

1%

50

x

B

B

B

-

B2-03

DC Injection Time
at Start
(DCInj Time
@Start)

0.00~
10.00

0.01s

0.00

x

B

B

B

B

B2-04

DC Injection
Braking Time at
Stop
(DCInj Time
@Stop)

0.00~
10.00

0.01s

0.50 *

* When 02-09 = 1 (American),
the setting is 0.00s. <24>

x

B

B

B

B

B2-08

<1110>

Magnetic Flux Com-
pensation Capacity
(Field Comp)

0~500

1%

0

100% is no-load current value
at Min. frequency (E1-09)

x

-

-

A

A

Speed S

earc

h

B3-01

Speed Search
Selection at Start
(SpdSrch at Start)

0,1

1

0*

0: Disabled
1: Enabled
* Factory setting defaults to 0:
Disabled except when (A1-
02=1) (V/F w/PG Fdbk) or 3
(Flux Vector).

x

A

A

A

A

B3-02

Speed Search
Operation Current
(SpdSrch Current)

0~200

1%

150*

* Factory setting defaults to 150
when A1-02=0 (V/F Control).
When A1-02=2 (Open Loop
Vector), the default is 100.

x

A

-

A

-

B3-03

Speed Search
Deceleration Time
(SpdSrch Dec
Time)

0.1~
10.0

0.1s

2.0

x

A

-

A

-

Del

ay

T

imers

Brak

e Se

quenc

e

B4-01

Timer Function
On-delay Time
(Delay-ON Timer)

0.0~

300.0

0.1s

0.0

x

A

A

A

A

B4-02

Timer Function
Off-delay Time
(Delay-OFF Timer)

0.0~

300.0

0.1s

0.0

x

A

A

A

A

Function

Parameter

No.

Name

(Digital Operator

Display)

Setting

Range

Setting

Unit

Factory

Setting

Remarks

(Digital Operator Display)

Change

during

Operation

o: Enabled

x: Disabled

Parameter Access Level

User

Setting

V/f

V/f

w/

PG

Open

Loop

Vector

Flux

Vector

Appendix

VS-616G5 Parameters

Advertising