Yaskawa VS-616G5 Series Revision F Quick-Start User Manual

Page 83

Advertising
background image

80

VS-616G5 Installation & Quick-Start Manual

Gr

oup b Ap

pl

ic

ati

on

PID

Cont

rol

B5-12

<1110>

PID Feedback Ref-
erence Missing
Detection Selection
(Fb Los Det Sel)

0~2

1

0

0: PID feedback missing

detection disabled. (Dis-
abled)

1: PID feedback missing

detection enabled. (Alarm)
Operation continues after
detection, “Fbl” alarm is dis-
played.

2: PID feedback missing

detection enabled. (Fault)
Inverter output is shut off

after detection, “Fbl” is dis-

played.

x

A

A

A

A

B5-13

<1110>

PID Feedback Ref-
erence Missing
Detection Level
(Fb los Det Lvl)

0~100

1%

0

x

A

A

A

A

B5-14

<1110>

PID Feedback Ref-
erence Missing
Detection Time
(Fb los Det Time)

0.0~
25.5

0.1s

1.0

x

A

A

A

A

Fu

nc

tion

b6 Ref

erenc

e H

ol

d

B6-01

Dwell Frequency at
Start
(Dwell Ref @Start)

0.0~

400.0

0.1Hz

0.0

x

A

A

A

A

B6-02

Dwell Time at Start
(Dwell Time @
Start)

0.0~
10.0

0.1s

0.0

x

A

A

A

A

B6-03

Dwell Frequency at
Stop
(Dwell Ref @ Stop)

0.0~

400.0

0.1Hz

0.0

x

A

A

A

A

B6-04

Dwell Time at Stop
(Dwell Time @
Stop)

0.0~
10.0

0.1s

0.0

x

A

A

A

A

Func

tion b7 D

roop

Contr

ol

D

roop

Contr

ol

B7-01

Droop Control Gain
(Droop Quantity)

0.0~

100.0

0.1%

0.0

o -

-

-

A

B7-02

Droop Control
Delay Time
(Droop Delay Time)

0.03~

2.00

0.01s

0.05

o

-

-

-

A

Function

Parameter

No.

Name

(Digital Operator

Display)

Setting

Range

Setting

Unit

Factory

Setting

Remarks

(Digital Operator Display)

Change

during

Operation

o: Enabled

x: Disabled

Parameter Access Level

User

Setting

V/f

V/f

w/

PG

Open

Loop

Vector

Flux

Vector

Appendix

VS-616G5 Parameters