Yaskawa VS-616G5 Series Revision F Quick-Start User Manual
Page 84

VS-616G5 Installation & Quick-Start Manual
81
Gr
oup b Ap
pl
ic
ati
on
Fu
nc
tion b
8 Ener
gy
S
av
ing
B8-01
Energy-saving Gain
(Energy Save Gain)
0~100
1%
80
—
x
A
A
-
-
B8-02
Energy-saving
Frequency
(Energy Save Freq)
0.0~
400.0
0.1Hz
0.0
—
x
A
A
-
-
B8-03
<1110>
Energy -saving
Mode Selection
0, 1
1
0
0: (Disabled)
1: (Enabled)
x
-
-
F (A)
Note
F (A)
Note
B8-04
<1110>
Energy-saving Con-
trol Gain (Energy
Save Gain)
0.0~
10.0
0.1
0.7*
*When control mode A1-
02 = 3, default factory
setting becomes1.0
o -
-
F (A)
Note
F (A)
Note
B8-05
<1110>
Energy-saving Con-
trol Time Constant
(Energy Save F .T)
0.00~
10.00
0.01s
0.50*
*When control mode A1-
02 = 3, default factory
setting becomes.01
o
-
-
F (A)
Note
F (A)
Note
Ze
ro
S
erv
o
B9-01
Zero-servo gain
(Zero Servo Gain)
0~100
1
5
—
x
-
-
-
A
B9-02
Zero-servo
Completion Width
(Zero Servo Count)
0~
16383
1
10
—
x
-
-
-
A
Note: USA (02x09=1) and EUR. (02x09=2) are
Advanced, others are Factory setting.
Function
Parameter
No.
Name
(Digital Operator
Display)
Setting
Range
Setting
Unit
Factory
Setting
Remarks
(Digital Operator Display)
Change
during
Operation
o: Enabled
x: Disabled
Parameter Access Level
User
Setting
V/f
V/f
w/
PG
Open
Loop
Vector
Flux
Vector
Appendix
VS-616G5 Parameters