VS-616G5 Installation & Quick-Start Manual

81

Gr

oup b Ap

pl

ic

ati

on

Fu

nc

tion b

8 Ener

gy

S

av

ing

B8-01

Energy-saving Gain
(Energy Save Gain)

0~100

1%

80

x

A

A

-

-

B8-02

Energy-saving
Frequency
(Energy Save Freq)

0.0~

400.0

0.1Hz

0.0

x

A

A

-

-

B8-03

<1110>

Energy -saving
Mode Selection

0, 1

1

0

0: (Disabled)
1: (Enabled)

x

-

-

F (A)

Note

F (A)

Note

B8-04

<1110>

Energy-saving Con-
trol Gain (Energy
Save Gain)

0.0~
10.0

0.1

0.7*

*When control mode A1-
02 = 3, default factory
setting becomes1.0

o -

-

F (A)

Note

F (A)

Note

B8-05

<1110>

Energy-saving Con-
trol Time Constant
(Energy Save F .T)

0.00~
10.00

0.01s

0.50*

*When control mode A1-
02 = 3, default factory
setting becomes.01

o

-

-

F (A)

Note

F (A)

Note

Ze

ro

S

erv

o

B9-01

Zero-servo gain
(Zero Servo Gain)

0~100

1

5

x

-

-

-

A

B9-02

Zero-servo
Completion Width
(Zero Servo Count)

0~

16383

1

10

x

-

-

-

A

Note: USA (02x09=1) and EUR. (02x09=2) are
Advanced, others are Factory setting.

Function

Parameter

No.

Name

(Digital Operator

Display)

Setting

Range

Setting

Unit

Factory

Setting

Remarks

(Digital Operator Display)

Change

during

Operation

o: Enabled

x: Disabled

Parameter Access Level

User

Setting

V/f

V/f

w/

PG

Open

Loop

Vector

Flux

Vector

Appendix

VS-616G5 Parameters