VS-616G5 Installation & Quick-Start Manual

39

2.1

TRIAL OPERATION

To ensure safety, prior to initial operation, disconnect the machine coupling so that the motor is iso-
lated from the machine. If initial operation must be performed while the motor is still coupled to the
machine, use great care to avoid potentially hazardous conditions. Check the following items before a
trial run:

· Wiring and terminal connections are proper.
· Wire clippings and other debris removed from the unit.
· Screws are securely tightened.
· Motor is securely mounted.
· All items are correctly grounded.

Digital Operator Display at Power-Up

When the system is ready for operation, turn ON the power supply. Verify that the inverter powers up
properly. If any problems are detected, turn OFF the power supply immediately. The digital operator
display illuminates as shown below when the power supply is turned ON.