Yaskawa VS-616G5 Series Revision F Quick-Start User Manual

Page 66

Advertising
background image

VS-616G5 Installation & Quick-Start Manual

63

4.1

MAINTENANCE & INSPECTION

This section describes basic maintenance and inspection procedures for the VS-616G5.

Periodic Inspection

The VS-616G5 will function longer if it is kept clean, cool and dry, and if all precautions highlighted
in this manual are observed. Periodically inspect the inverter as described in the table below to prevent
accidents and to ensure high performance with high reliability.
To prevent electrical shock, disconnect all power before servicing the inverter. Then wait at least five
minutes after the power supply is disconnected and all LEDs are extinguished.

Parts Replacement Schedule

Replace the following parts periodically, for long, safe, trouble-free operation of the VS-616G5:

Optimum operating conditions:

Ambient temperature: 86°F yearly average
Load factor:

80% or below

Operation rate:

12 hours or less per day

Component

Check

Corrective Action

External Terminals,
Connectors, Mounting
Screws, etc.

Loose screws or connectors

Securely tighten.

Heatsink

Build-up of dust and dirt

Blow with dry, compressed air [39.2
× 10

4

to 58.8

× 10

4

Pa (4 to 6kg·cm

2

)

pressure].

Printed Circuit Board
(PCB)

Accumulation of conductive dust or oil

Blow with dry, compressed air [39.2
× 10

4

to 58.8

× 10

4

Pa (4 to 6kg·cm

2

)

pressure]. If dust and oil cannot be
removed, replace the board.

Cooling Fan

For abnormal noise and vibration

Replace the cooling fan.

Power Components

Accumulation of dust and dirt

Blow with dry, compressed air [39.2
× 10

4

to 58.8

× 10

4

Pa (4 to

6kg·cm2) pressure].

Smoothing Capacitor

Discoloration or odor

Replace the capacitor or the inverter.

Parts

Approximate Interval

Remarks

Cooling Fan

2 to 3 years

Replace with new one.

Smoothing Capacitor

5 years

Replace with new one (after inspection).

Breakers or Relays

--

Decide after inspection.

Fuses

10 years

Replace with new one.

Aluminum Electrolytic
Capacitor on PCB Board

5 years

Replace with new one (after inspection).

Chapter 4 - Diagnostics

Maintenance & Inspection