C4-01

Torque Compensa-
tion Gain
(Torq Comp Gain)

0.00~

2.50

0.01

1.00

o

B

B

B

-

C4-02

Torque Compensa-
tion Time
(Torq Comp Time)

0~10000 1 ms

20*

* When A1-02=2 [Open Loop
Vector] factory default setting is
20 ms. When A1-02=1or 3 [V/
F or V/F w/PG] factory default
setting is 200 ms.

x

A

A

A

-

C4-03

<1110>

Forward Torque
Compensation
Value @ Start
(F TorqCmp @start)

0.0~

200.0

0.1%

0.0

Functions only when starting a
motor. Torque reference and
motor flux can be ramped up
quickly to improve speed
response during start. A set-
ting of 0.0 disables this feature.

x

-

-

A

-

C4-04

<1110>

Reverse Torque
Compensation
Value @ Start.
(R TorqCmp @
start)

200.0~

0.0

0.1%

0.0

Functions only when starting a
motor. Torque reference and
motor flux can be ramped up
quickly to improve speed
response during start. A set-
ting of 0.0 disables this feature.

x

-

-

A

-

C4-05

<1110>

Torque Compensa-
tion Time Constant
(TorqCmp Delay T)

0~200

1ms

10

When 0~4ms is set, it is oper-
ated without filter. Functions
with C4-03 and C4-04.

x

-

-

A

-

Fu

nc

tion

C5 ASR

Tuni

ng

C5-01

ASR Proportional
(P) Gain 1
(ASR P Gain 1)

0.00~

300.00

0.01

20.00*

When A1-02=1 [V/f w/PG] fac-
tory default setting is .20.
When A1-02=3 factory default
setting is 20.00.

o

-

B

-

B

C5-02

ASR Integral (I)
Time 1
(ASR 1 Time 1)

0.000~
10.000

0.001s 0.500*

When A1-02=1 [V/f w/PG] fac-
tory default setting is .200.
When A1-02=3 factory default
setting is .500

o

-

B

-

B

C5-03

ASR Proportional
(P) Gain 2
(ASR P Gain 2)

0.00~

300.00

0.01

20.00*

When A1-02=1 [V/f w/PG] fac-
tory default setting is .02 When
A1-02=3 factory default setting
is 20.00.

o

-

B

-

B

C5-04

ASR Integral (I)
Time 2
(ASR 1 Time 2)

0.000~
10.000

0.001s 0.500*

When A1-02=1 [V/f w/PG] fac-
tory default setting is .050.
When A1-02=3 factory default
setting is .500.

o

-

B

-

B

C5-05

ASR Limit
(ASR Limt)

0.0~
20.0

0.1%

5.0

x

-

A

-

-

C5-06

ASR Primary Delay
Time
(ASR Delay Time)

0.000~

0.500

0.001s

0.004

x

-

-

-

A

C5-07

ASR Switching
Frequency
(ASR Gain SW Freq)

0.0~

400.0

0.1Hz

0.0

x

-

-

-

A

C5-08

ASR Integral Limit
(ASR I Limit)

0~400

1

400%

x

-

-

-

A

Function

Parameter

No.

Name

(Digital Operator

Display)

Setting

Range

Setting

Unit

Factory

Setting

Remarks

(Digital Operator Display)

Change

during

Operation

o: Enabled

x: Disabled

Parameter Access Level

User

Setting

V/f

V/f

w/

PG

Open

Loop

Vector

Flux

Vector

Appendix

VS-616G5 Parameters

Advertising