Yaskawa VS-616G5 Series Revision F Quick-Start User Manual

Page 104

Advertising
background image

VS-616G5 Installation & Quick-Start Manual

101

Prote

cti

on

Func

tion L3

Stal

l Pr

ev

en

tio

n Fu

nc

tion

L3-01

Stall Prevention
During Acceleration
(StallP Accel Sel)

0, 1, 2

1

1

0: (Disabled)
1: (General Purpose)
2: (Intelligent)

x

B

B

B

-

L3-02

Stall Prevention
Level During Accel-
eration
(StallP Accel Lvl)

0~200

1%

150

x

B

B

B

-

L3-03

Stall Prevention
Limit During Accel-
eration
(StallP CHP Lvl)

0~100

1%

50

x

A

A

A

-

L3-04

Stall Prevention
During Deceleration
(StallP Decel Sel)

0, 1, 2, 3

1

1

0: (Disabled)
1: (General Purpose)
2: (Intelligent)

<1110>

can use setting 2 for

all control modes
A102=0,1,2,3

3: With braking resistor
(Stall prev w/R)
When in Vector w/PG A1-

02=3 setting 3 cannot be set
with braking resistor and
with stall prevention.

x

B

B

B

B

L3-05

Stall Prevention
Selection during
Running
(StallP Run Sel)

0, 1, 2

1

1

0: (Disabled)
1: (Decel Time 1) C1-02
2: (Decel Time 2) C1-04

x

B

B

-

-

L3-06

Stall Prevention
Level during
Running
(StallP Run Level)

30~200

1%

160

x

B

B

-

-

L3-07

Stall Prevention
Function P Gain
(StallP Gain)

0.10~

2.00

0.01

1.00

x

F

F

-

-

L3-08

Stall Prevention
Function Integral
Time
(StallP Intg Time)

10~250

1 ms

100

x

F

F

-

-

Function

Parameter

No.

Name

(Digital Operator

Display)

Setting

Range

Setting

Unit

Factory

Setting

Remarks

(Digital Operator Display)

Change

during

Operation

o: Enabled

x: Disabled

Parameter Access Level

User

Setting

V/f

V/f

w/

PG

Open

Loop

Vector

Flux

Vector

Appendix

VS-616G5 Parameters

Advertising