V/F Patterns for Inverter Capacity 2.2 ~ 45kW for 230V Class*

Parameter

No.

Name

Unit

Factory Setting

E1-03

V/f Pattern Selection

0

1

2

3

4

5

6

7

E1-04

Max. Output Frequency

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

E1-05

Max. Voltage

V

230.0

230.0

230.0

230.0

230.0

230.0

230.0

230.0

E1-06

Max. Voltage Frequency

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

E1-07

Mid. Output Frequency

V

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

E1-08

Mid. Output Frequency Voltage

V

16.1

16.1

16.1

16.1

40.2

57.5

40.2

57.5

E1-09

Min. Output Frequency

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

E1-10

Min. Output Frequency Voltage

V

8.0

8.0

8.0

8.0

6.9

8.0

6.9

8.0

V/F Patterns for Inverter Capacity 2.2 ~ 45kW for 230V Class* (Continued)

Parameter

No.

Name

Unit

Factory Setting

E1-03

V/f Pattern Selection

8

9

A

B

C

D

E

F

E1-04

Max. Output Frequency

Hz

50.0

50.0

60.0

60.0

90.0

120.0

180.0

60.0

E1-05

Max. Voltage

V

230.0

230.0

230.0

230.0

230.0

230.0

230.0

230.0

E1-06

Max. Voltage Frequency

Hz

50.0

50.0

60.0

60.0

60.0

60.0

60.0

60.0

E1-07

Mid. Output Frequency

V

2.5

2.5

3.0

3.0

3.0

3.0

3.0

3.0

E1-08

Mid. Output Frequency Voltage

V

20.7

26.4

20.7

26.4

16.1

16.1

16.1

16.1

E1-09

Min. Output Frequency

Hz

1.3

1.3

1.5

1.5

1.5

1.5

1.5

1.5

E1-10

Min. Output Frequency Voltage

V

10.3

12.6

10.3

14.9

8.0

8.0

8.0

8.0

Chapter 3 - Quick-Start Programming