TA Triumph-Adler P-C3560i MFP User Manual

Page 366

Advertising
background image

10-23

Troubleshooting > Troubleshooting

S

Replace MK.

Replacement of the parts in the
maintenance kit is necessary at
every 200,000 pages (P-C3560i
MFP/P-C3565i MFP) of printing and
requires professional servicing.
Contact your Service
Representative.

Running security
function...

Running security function. Please
wait.

*1 When Auto Error Clear is set to [On], processing resumes automatically after a set amount of time elapses. For details

on Auto Error Clear, refer to the following:

Auto Error Clear (page 8-39)

Message

Checkpoints

Corrective Actions

Reference

Page

Scanner memory is
full.

*1

Scanning cannot be performed due
to insufficient memory of scanner.
Only one copy of the scanned
pages is available. Select
[Continue] to print, send or store
the scanned pages. Select [Cancel]
to cancel the printing job.
The machine may reproduce the
same originals by arranging the
following settings:

Reduce the number of originals
to be scanned at once.
Furthermore, the machine may
reproduce the same originals by
arranging the following settings:

Select [Copy Priority] of
Optional Memory in System
Menu.

NOTE

Before changing the Optional
Memory setting, contact your
administrator.

Send Error.

*2

An error has occurred during
transmission. The job is canceled.
Select [End].
Refer to

Responding to Send Error

for the error code and corrective
actions.

page 10-26

Shake the toner
container. [C][M][Y][K]

Shake the toner container well and
reinstall it.

page 10-4

Message

Checkpoints

Corrective Actions

Reference

Page

Advertising