PLANET IGS-10020HPT User Manual

Page 111

Advertising
background image

User’s Manual of IGS-10020HPT

Receive and Transmit Size Counters

The number of received and transmitted (good and bad) packets split into categories based on their respective frame

sizes.

Receive and Transmit Queue Counters

The numeric of received and transmitted packet is per input and output queue.

Receive Error Counters

Object

Description

Rx Drops

The numeric of frames is dropped due to lack of receive buffers or egress

congestion.

Rx CRC/Alignment

The number of frames received with CRC or alignment errors.

Rx Undersize

The number of short

1

frame received with valid CRC.

Rx Oversize

The number of long

2

frame received with valid CRC.

Rx Fragments

The number of short

1

fram received with invalid CRC.

Rx Jabber

The number of long

2

frame received with invalid CRC.

Rx Filtered

The number of received frames filtered by the forwarding process.

Short frames are frames that are smaller than 64 bytes.

Long frames are frames that are longer than the configured maximum

frame length for this port.

1 Short frame is the frames that are smaller than 64 bytes.

2 Long frames are frames that are longer than the configured maximum frame length for this port.

Transmit Error Counters

Object

Description

Tx Drops

The number of frames dropped due to output buffer congestion.

Tx Late/Exc. Coll.

The number of frames dropped due to excessive or late collisions.

Buttons

: Click to refresh the page immediately.

: Clears the counters for all ports.

Auto-refresh

: Check this box to enable an automatic refresh of the page at regular intervals.

111