Dido do power alarm, Dido fault act – PLANET IGS-10020HPT User Manual

Page 581

Advertising
background image

User’s Manual of IGS-10020HPT

DIDO DO Power Alarm

Description:

Set or show the system digital output0/1 power alarm.

Syntax:

DIDO Do_pwr_alr [first|second] [dc1|dc2] [enable|disable]

Parameters:

first

: Digital Input/Output 0

second

: Digital Input/Output 1

(default: Set or show digital input/output first(0)/second(1) select)

dc1

: DC power 1

dc2 :

DC power 2

(default: Set or show digital output/fault alarm 0/1 power_fail)

enable

: Enable digital input0/1 function

disable

: Disable digital input0/1 function

(default: Set or show digital input/output/fault alarm 0/1 status)

DIDO Fault Act

Description:

Set or show the system fault alarm action.

Syntax:

DIDO Fault_act [port|power] [enable|disable]

Parameters:

port

: port fail

power

: power fail

DI1

: DI1 trigger

DI2

: DI2 trigger

(default: Set or show digital output/fault alarm 0/1 action)

enable

: Enable digital input0/1 function

disable

: Disable digital input0/1 function

(default: Set or show digital input/output/fault alarm 0/1 status)