2 status – PLANET IGS-10020HPT User Manual

Page 343

Advertising
background image

User’s Manual of IGS-10020HPT

Shutdown Time

The period (in seconds) for which a port will be kept disabled in the event of a

loop is detected (and the port action shuts down the port). Valid values are 0 to

604800 seconds (7 days). A value of zero will keep a port disabled (until next

device restart).

Port Configuration:

Object

Description

Port

The switch port number of the port.

Enable

Controls whether loop protection is enabled on this switch port.

Action

Configures the action performed when a loop is detected on a port. Valid values

are Shutdown Port, Shutdown Port and Log or Log Only.

Tx Mode

Controls whether the port is actively generating loop protection PDU's, or

whether it is just passively looking for looped PDU's.

Buttons

: Click to save changes.

:

Click to undo any changes made locally and revert to previously saved values.

4.17.2 Status

This page displays the loop protection port status the ports from the Industrial Managed Switch.

Figure 4-17-2:

Loop Protection Status Page Screenshot

The page includes the following fields:

Object

Description

Port

The switch port number of the logical port.

Action

The currently configured port action.

Transmit

The currently configured port transmit mode.