PLANET IGS-10020HPT User Manual

Page 85

Advertising
background image

User’s Manual of IGS-10020HPT

The page includes the following fields:

Object

Description

Enable

Checks the Enable checkbox will enable Digital Input / output function.

Unchecks the Enable checkbox will disable Digital input / output function.

Condition

As Digital Input:

Allows user selecting to High to Low or Low to High. This is means a signal

received by system is from High to Low or From Low to High, it will trigger an

action that logs a customize message or issue the message from the switch.

As Digital Output:

Allows user selecting to High to Low or Low to High. This is means

that when

the switch has power failed or port failed then system will issue a High

or Low signal to an external device (such as an alarm).

Event Description

Allows user setting a customize message for Digital Input function alarming.

Event

As Digital Input:

Allows user to record alarm message to System log, syslog or issues out via

SNMP Trap or SMTP.

As default SNMP Trap and SMTP are disabled, please enable them first if you

want to issue alarm message via them.

As Digital Output:

Allows user to monitor and alarm from port fail, power fail, Digital Input 0 (DI 0)

and Digital Input 1(DI 1) which means if Digital Output has detected these

event then Digitial Output would be triggered according to the setting of

Condition.

Power Alarm

Allows user to choose which power module want to be monitored.

Port Alarm

Allows user to choose which port want to be monitored.

Buttons

: Click to save changes.

: Click to undo any changes made locally and revert to previously saved values.

85

Advertising