Chapter 6. Port Access
105
Power Management
If a PN0108 is connected to the KVM over IP switch, and a device is connected
to one of the PN0108’s outlets, you can power manage (On, Off, Reboot)
selected outlets directly from this page, instead of having to select them on the
PON device, itself.
Associating outlets with a port is accomplished on the
Port Access
→
Port
Configuration
→
Power Management
page (see page 132 for details).
If there is more than one outlet associated with this port, click on the line
entry to select the one you want to manage, then click the
On
,
Off
, or
Reboot
icon, as appropriate.
Note:
For the Reboot option, the outlet must be configured with
System
After AC Back
or
Modem Ring Resume
as its operating mode.
If there is more than one outlet associated with this port, and you want to
power manage several of them at once, use
Shift-Click
(for a sequential
set), or
Ctrl-Click
(for a non-sequential set) to select your group.
If there is more than one outlet associated with this port, and you want to
power manage all of them at once, click to put a checkmark in the
Select
All
checkbox.
Note:
1. Even though the outlets all turn On, Off, or Reboot at the same
time, they do so with their own separate outlet configuration
settings (delay, operating mode, etc. See
2. For the Reboot option, the outlet must be configured with
System
After AC Back
or
Modem Ring Resume
as its operating mode.
The
Synchronization
checkbox is read only. Whether it is enabled or not is
set on the
Port Configuration
→
Power Management
When Synchronization is enabled, the outlets on devices with more than
one power supply can all be operated at the same time.
Note:
For the Reboot option, the outlets must be configured with
System
After AC Back