Mechanical Installation

MultiVOIP User Guide

106

If you are connecting an E&M trunk from a telephone switch to your
MultiVOIP, connect one end of an RJ-45 phone cord to the Channel 1 E&M
connector on the back of the MultiVOIP and the other end to the trunk.
Verify that the E&M Type in the E&M Options group of the Interface dialog
box is the same as the E&M trunk type support by the telephone switch. See
Appendix B for an E&M cabling pinout.

5. Repeat the above step to connect the remaining telephone equipment to the

second channel on your MultiVOIP.

6. Ensure that the unit is properly connected to earth ground by verifying that it

is reliably grounded when mounted within a rack.

This can be accomplished by connecting a grounding wire between the
chassis and a metallic object that will provide an electrical ground.

7. Turn on power to the MultiVOIP by placing the ON/OFF switch on the back

panel to the ON position. Wait for the BOOT LED on the MultiVOIP to go
off before proceeding. This may take a few minutes.

Proceed to Chapter 4 to load the MultiVOIP software.