396

T1 Statistics: Field Definitions (cont’d)

Field
Name

Values

Description

Yellow Alarm

Tally since last
reset.

The alarm signal sent by a remote T1/E1
device to indicate that it sees no receive signal
or cannot synchronize on the receive signal.

Frame Search
Restart Flag

[To be supplied.]

Loss of
MultiFrame
Alignment

Tally since last
reset.

In D4 or ESF mode, displayed value will
increment if multiframe alignment has been
lost or if loss of frame alignment has been
detected.

Transmit Slip

Tally since last
reset.

Slip in transmitted data stream. Slips indicate
a clocking mismatch (or lack of
synchronization) between T1/E1 devices.
When slips occur, data may be lost or
repeated.

Pulse Density
Violation

The pulse density of the received data stream
is below the requirement defined by ANSI
T1.403 or more than 15 consecutive zeros are
detected.

Line
Loopback
Activation
Signal

The line loopback activation signal has
been detected in the received bit stream.

Transmit Line
Open

At least 32 consecutive zeros were
transmitted.

Transmit Data
Underrun

For use by MTS Technical Support
Personnel.

Transmit Slip
Negative

The frequency of the transmit clock is
greater than the frequency of the transmit
system interface working clock. A frame
is skipped.