Voice/Fax Parameter Definitions (cont’d) )

Field Name

Values

Description

Auto Disconnect

Automatic
Disconnect-
ion

--

The Automatic Disconnection group
provides four options which can be
used singly or in any combination.

Jitter Value

1-65535
milli-
seconds

The Jitter Value defines the average
inter-arrival packet deviation (in
milliseconds) before the call is
automatically disconnected. The default
is 150 milliseconds. A higher value
means voice transmission will be more
accepting of jitter. A lower value is less
tolerant of jitter.
Inactive by default. When active,
default = 150 ms. However, value must
equal or exceed Dynamic Minimum
Jitter Value.

Call Duration

1-65535
seconds

Call Duration defines the maximum
length of time (in seconds) that a call
remains connected before the call is
automatically disconnected.
Inactive by default.
When active, default = 180 sec.
This may be too short for most
configurations requiring upward
adjustment.

Consecutive
Packets Lost

1-65535

Consecutive Packets Lost defines the
number of consecutive packets that are
lost after which the call is automatically
disconnected.
Inactive by default.
When active, default = 30

Network
Discon-
nection

1 to 65535
seconds;
Default =
300 sec.

Specifies how long to wait before
disconnecting the call when IP network
connectivity with the remote site has
been lost.