MultiVOIP User Guide

E1 PhoneBook Configuration

361

The Inbound PhoneBook of the MVP3010 is shown below.

Inbound Phone Book for MVP3010 Digital VOIP (Site D)

Remove
Prefix

Add
Prefix

Channel
Number

Comments

0207

9,7
Note 4.
Note 5.

0

Allows phone users at remote voip sites to
call local numbers (those within the Site D
area code, 0207, Inner London) over the
VOIP network.

0208

9,8
Note 4.
Note 5.

0

Allows phone users at remote voip sites to
call local numbers (those in Outer London)
over the VOIP network.

0207
39883

3

0

Allows phone users at remote voip sites to
call extensions of the Site D PBX using
three digits, beginning with “3” .

Note 4. “9” gives PBX station users access to outside line.
Note 5. The comma represents a one-second pause, the time required for
the user to receive a dial tone on the outside line (PSTN). Commas can be
used in the Inbound Phonebook, but not in the Outbound Phonebook.