Technical Configuration (Analog/BRI) MultiVOIP User Guide

258

If you enable console messages, you can customize the types of messages to
be included/excluded in log reports by clicking on the “Filters” button and
using the Console Messages Filter Settings screen (see subsequent page).
If you use the logging function, select the logging option that applies to your
VoIP system design. If you intend to use a SysLog Server program for
logging, click in that Enable check box. The common SysLog logical port
number is 514. If you intend to use the MultiVOIP web browser GUI for
configuration and control of MultiVOIP units, be aware that the web browser
GUI does not support logs directly. However, when the web browser GUI is
used, log files can still be sent to the voip administrator via email (which
requires activating the SMTP logging option in this screen).