Technical Configuration (Digital Voips)

MultiVOIP User Guide

152

T1 Parameter Definitions (cont’d)

Field Name

Values

Description

Line Build Out

0 dB, -7.5 dB,
-15 dB, -22.5 dB

To reduce the crosstalk on received
signals, a transmit attenuator can
be placed in the data path.
Transmit attenuation is selectable.
Default: O dB

Pulse Shape
Level

0 to 40 Meters
40 to 81 m
81 to 122 m
122 to 162 m
162 to 200 m

Refers to length of cable
between MultiVOIP and
PBX/telco in meters. Most
common will be 0 to 40m.

Clocking

External/Internal

Set opposite to telco/PBX setting.
Example: if telco clocking internal,
set VOIP clocking as external.

Line Coding

AMI / B8ZS

Match to PBX or telco.

PCM Law

A-Law/Mu-Law

Match to PBX or telco. “
Mu-law” is analog-to-digital
compression/expansion
standard used in North America.
“A-law” is European standard.

Yellow Alarm
Format

Bit 2 / 1111…

Depending on the Frame Format
used, there are choices of Yellow
Alarm format, as follows:
D4: -Bit2 = 0 in every speech

channel
-FS bit of frame 12 is forced to
one.

ESF: -Bit2 = 0 in every speech

channel
–1111111100000000 pattern in
data link channel.

Check with your PBX/telco
administrator for the correct setting
or use the default value (1111 … ).