Multi-Tech Systems MULTIVOIP MVP-2410 User Manual

Page 234

Advertising
background image

Technical Configuration (Analog/BRI) MultiVOIP User Guide

234

E&M Interface Parameter Definitions

Field Name

Values

Description

Interface

E&M

enables E&M functionality

Type

Types 1-5. Each
type can be 2-wire
or 4-wire.

Refers to the type of E&M
interface being used.

Signal

Dial Tone or
Wink

When Dial Tone is selected, no
wink is required on the E lead or M
lead in the call initiation or setup.
When Wink is selected, a wink is
required during call setup.

Wink Timer
(in ms)

integer values,
in milliseconds

This is the length of the wink for
wink signaling.
Applicable only when Signal
parameter is set to “Wink.”

Pass Through

Y/N

When enabled (“Y”), this feature is
used to create an open audio path
for 2- or 4-wire. The E&M leads
are passed through the voip
transparently.
Applicable only for E&M
Signaling with Dial Tone.

Advertising