Multi-Tech Systems MULTIVOIP MVP-2410 User Manual

Page 157

Advertising
background image

MultiVOIP User Guide

Technical Configuration (Digital Voips)

157

E1 Parameter Definitions (cont’d)

Field Name

Values

Description

Line Build Out

0 dB, -7.5 dB,
-15 dB, -22.5 dB

To reduce the crosstalk on received
signals, a transmit attenuator can
be placed in the data path.
Transmit attenuation is selectable.
Default: O dB

Pulse Shape
Level

0 to 40 Meters
40 to 81 m
81 to 122 m
122 to 162 m
162 to 200 m

Refers to length of cable
between MultiVOIP and
PBX/telco in meters. Most
common will be 0 to 40m.

Clocking

External/Internal

Set opposite to telco/PBX setting.
Example: if telco clocking internal,
set VOIP clocking as external.

Line Coding

AMI / HDB3

Match to PBX or telco.

PCM Law

A-Law/Mu-Law

Match to PBX or telco.
“A-law” is analog-to-digital
compression/expansion
standard used in Europe.
“Mu-law” is North American
standard.

Advertising