Multi-Tech Systems MULTIVOIP MVP-2410 User Manual

Page 333

Advertising
background image

MultiVOIP User Guide

E1 PhoneBook Configuration

333

The table below describes all fields in the PhoneBook Configuration screen.

PhoneBook Configuration Parameter Definitions

Field Name

Values

Description

Gateway Name

Y/N

This field allows you to specify a name for this
MultiVOIP. When placing a call, this name is
sent to the remote MVP3000 for display in Call
Progress listings, Logs, etc.

Q.931 Parameters

Use Fast Start

Y/N

Enables the H.323 Fast Start procedure. May
need to be enabled/disabled for compatibility
with third-party VOIP gateways.

Call Signaling
Port

port

number

Default: 1720 (H.323)

GateKeeper RAS

Parameters

Gatekeeper /
Clear Channel
IP Address

IP address of the GateKeeper.

Port Number

Well-known port number for GateKeepers.
Must match port number of GateKeeper, 1719.

Gateway Prefix

This number becomes registered with the
GateKeeper. Call requests sent to the gatekeeper
and preceded by this prefix will be routed to the
VOIP gateway.

Gatekeeper
Name

alpha-

numeric
string

Optional. The name of the GateKeeper with
which this MultiVOIP is trying to register.

Gateway H.323
ID

The H.323 ID is used to register this particular
MultiVOIP with the GateKeeper. H.323 ID is an
alias entry sent to the GateKeeper, made of
alphanumeric characters. For NetMeeting
endpoints, numbers are preferred over letters.
The H.323 ID identifies the IP calling sequence
that the GateKeeper must ‘dial’ to contact the
remote VOIP.

Advertising