<Operating conditions>

The number of motor poles should be any of 2, 4 and 6 poles.

Single-motor operation (One motor for one inverter)

The wiring length from inverter to motor should be within 30m (98.42feet).

<Setting>

Parameter

Setting

Description

- - -

Ordinary V/F control and torque boost (Pr. 0, Pr. 46) are valid.

98

0.1 to 3.7kW

(*)

Automatic torque boost control valid

(Set the applied motor capacity or one rank lower motor capacity.)

* The setting range changes with the inverter: 0.2kW to 3.7kW, - - - for the 400V

class.

Also when the Pr. 98 setting is other than "- - -", Pr. 3 "base frequency" and Pr. 19

"base frequency voltage" are valid.

When "- - -" or "888" is set in Pr. 19, the rated output voltage is selected.

CAUTION

* During operation using automatic torque boost, write to Pr. 3 and Pr. 19 is disabled

if "2" is set in Pr. 77.

Related parameters

Torque boost

Pr. 0 "torque boost", Pr. 46 "second torque boost" (refer to page 58)

Base frequency

Pr. 3 "base frequency", Pr. 19 "base frequency voltage" (refer to page 59)

Applied motor setting

Pr. 71 "applied motor" (refer to page 93)

Motor primary resistance

Pr. 99 "motor primary resistance" (refer to page 111)