MITSUBISHI ELECTRIC FR-S520 User Manual

Page 153

Advertising
background image

144

3

Operation Panel Indication

Er2

FR-PU04

In PU/EXT Mode
OPERATOR ERR

Name

Write-while-running error/mode designation error

Description

Write was performed during operation.
An attempt was made to change the Pr. 79 setting to the

operation mode where the operation command has been input.

Write was performed in the external operation mode.

Corrective action

After stopping operation, make parameter setting.
After setting the operation mode to the "PU operation mode",
make parameter setting. (Refer to page 98)

Operation Panel Indication

Er3

FR-PU04

Incr I/P

Name

Calibration error

Description

Analog input bias and gain calibration values are too close.

Corrective action

Check the settings of C3, C4, C6 and C7 (calibration functions).
(Refer to page 74)

Advertising