49

2

Func-

tion

Pa-

rame-

ter

Indica-

tion

Name

Setting Range

Minimum

Setting

Increments

Factory

Setting

<EC

version>

Refer

To:

Cus-

tomer

Setting

48

Output current
detection level

0 to 200%

1%

150%

80

49

Output current
detection
signal delay
time

0 to 10s

0.1s

0s

80

50

Zero current
detection level

0 to 200%

1%

5%

81

C

u

rr

en

t de

te

ction

51

Zero current
detection time

0.05 to 1s

0.01s

0.5s

81

52 *

Control panel
display data
selection

0: Output frequency,
1: Output current,
100: Set frequency

during stop/output
frequency during
operation

1

0

82

53 *

Frequency
setting
operation
selection

0: Setting dial

frequency setting
mode

1: Setting dial

potentiometer mode

1

0

83

54 *

FM (AM)
terminal
function
selection

0: Output frequency

monitor

1: Output current

monitor

1

0

82

55 *

Frequency
monitoring
reference

0 to 120Hz

0.1Hz

60Hz

<50Hz>

84

Di

s

p

la

y f

u

nc

ti

ons

56 *

Current
monitoring
reference

0 to 50A

0.1A

Rated

output

current

84

57

Restart
coasting time

0 to 5s, - - -

0.1s

- - -

84

A

u

to

ma

tic r

e

sta

rt

func

ti

o

n

s

58

Restart
cushion time

0 to 60s

0.1s

1s

84

Ad

di

ti

o

nal

f

u

nc

ti

on

59

Remote
setting
function
selection

0: Without remote

setting function

1: With remote setting

function
With frequency
setting storage
function

2: With remote setting

function
Without frequency
setting storage
function

1

0

86

Pammet

e

r Li

s

t

Advertising