MITSUBISHI ELECTRIC FR-S520 User Manual

Page 136

Advertising
background image

127

2

No.

Item

Instruction

Code

Description

Number

of Data

Digits

(Data

code

FF = 1)

4

Inverter status
monitor

H7A

b7

0

0

0

0

0

0

0

1

b0

[For example 1]

[Example 1] H02 ... During
forward
rotation
[Example 2] H80 ... Stop due to
alarm

b0: Inverter
running (RUN)*
b1: Forward rotation
b2: Reverse rotation
b3: Up to
frequency (SU)
b4: Overload (OL)
b5:
b6: Frequency
detection (FU)
b7: Alarm occurrence*

* Function change can be made using Pr. 64 and

Pr. 65 (output terminal function selection).

2 digits

Set frequency
read (E

2

PROM)

H6E

Set frequency
read (RAM)

H6D

Reads the set frequency (RAM or E

2

PROM).

H0000 to H2EE0: 0.01Hz increments
(hexadecimal)

4 digits
(6 digits)

Set frequency
write (RAM and
E

2

PROM)

HEE

5

Set frequency
write
(RAM only)

HED

H0000 to H2EE0: 0.01Hz increments
(hexadecimal) (0 to 120.00Hz)*
To change the set frequency consecutively, write
data to the inverter RAM. (Instruction code: HED)
* The minimum setting increments are 0.01Hz but

setting may be made in 0.1Hz increments only.

4 digits
(6 digits)

6

Inverter reset

HFD

H9696: Resets the inverter.
As the inverter is reset on start of communication
by the computer, the inverter cannot send reply
data back to the computer.

4 digits

7

Alarm definition
batch clear

HF4

H9696: Alarm history batch clear

4 digits

All parameters return to the factory settings.
Any of four different all clear operations are
performed according to the data.

Pr.

Data

Commu-

nication

Pr.

Calibra

-tion

Pr.

Other

Pr.*

HEC

HFF

H9696
H9966
H5A5A
H55AA

8

All parameter
clear

HFC

When all parameter clear is executed for H9696 or
H9966, communication-related parameter settings
also return to the factory settings. When resuming
operation, set the parameters again.
* Pr. 75 is not cleared.

4 digits

9

Parameter write

H80 to

HFD

10 Parameter read

H00 to

H7B

Refer to the "Data Code List" (page 177) and write
and/or read the values as required.