Functions 45 – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 7

Advertising
background image

II

1.8.3 Current input selection "AU signal": Setting "4"...................................... 38
1.8.4 Start self-holding selection (STOP signal): Setting "5"........................... 38
1.8.5 Output shut-off (MRS signal): Setting "6"................................................ 39
1.8.6 External thermal relay input: Setting "7".................................................. 39
1.8.7 Jog operation (JOG signal): Setting "9" .................................................. 40
1.8.8 Reset signal: Setting "10"......................................................................... 40
1.8.9 PID control valid terminal: Setting "14".................................................... 41
1.8.10 PU operation/external operation switching: Setting "16" ..................... 41

1.9 Handling of the RS-485 Connector

(Type with RS-485 Communication Function) .......................................41

1.10 Design Information ...............................................................................44

2. FUNCTIONS

45

2.1 Function (Parameter) List.......................................................................46
2.2 List of Parameters Classified by Purpose of Use...................................56
2.3 Explanation of Functions (Parameters)..................................................58

2.3.1 Torque boost

........................................................................... 58

2.3.2 Maximum and minimum frequency

....................................... 59

2.3.3 Base frequency, Base frequency voltage

.................... 59

2.3.4 Multi-speed operation

to

to

....... 61

2.3.5 Acceleration/deceleration time

................... 62

2.3.6 Electronic overcurrent protection

.................................................... 64

2.3.7 DC injection brake

......................................................... 64

2.3.8 Starting frequency

........................................................................... 65

2.3.9 Load pattern selection

..................................................................... 66

2.3.10 Jog frequency

....................................................................... 67

2.3.11

RUN

key rotation direction selection

............................................. 67

2.3.12 Stall prevention function and current limit function

...................... 68

2.3.13 Stall prevention

............................................................ 69

2.3.14 Acceleration/deceleration pattern

................................................. 71

2.3.15 Extended function display selection

............................................. 72

2.3.16 Frequency jump

to

............................................................... 72

2.3.17 Speed display

................................................................................ 73

2.3.18 Biases and gains of the frequency setting voltage (current)

to

.......................................................................... 74

2.3.19 Start-time ground fault detection selection

.................................. 78

2.4 Output Terminal Function Parameters ...................................................78

2.4.1 Up-to-frequency sensitivity

.............................................................. 78

2.4.2 Output frequency detection

.................................................... 79

2.5 Current Detection Function Parameters.................................................80

2.5.1 Output current detection functions

........................................ 80

2.5.2 Zero current detection

............................................................ 81

2.6 Display Function Parameters .................................................................82

2.6.1 Monitor display

........................................................................ 82

Advertising
This manual is related to the following products: