4) single-phase 100v power supply – MITSUBISHI ELECTRIC FR-S520 User Manual

Page 173

Advertising
background image

164

4

(4) Single-phase 100V power supply

Japanese version

FR-S510W-0.1K to 0.75K (-R)

NA version

FR-S510W-0.1K to 0.75K-NA

Type FR-S510W- K(-R)

0.1

0.2

0.4

0.75

kW

0.1

0.2

0.4

0.75

Applicable motor capacity

(*1)

HP

1/8

1/4

1/2

1

Rated capacity (kVA) (*2)

0.3

0.5

1.0

1.6

Rated current (A)

0.8

1.4

2.5

4.1

Overload capacity (*3)

150% 60s 200% 0.5s (Inverse time characteristics)

Out

put

Voltage

Three phase, 200V to 230V 50Hz/60Hz (*4, 6)

Rated input AC (DC) voltage,

frequency

Single-phase, 100V to 115V 50Hz/60Hz

Permissible AC (DC) voltage

fluctuation

90 to 132V 50Hz/60Hz

Permissible frequency

fluctuation

±

5%

Power

s

uppl

y

Power supply system

capacity (kVA) (*5)

0.5

0.9

1.5

2.5

Protective structure (JEM1030)

Enclosed type (IP20)

Cooling system

Self-cooling

Approximate weight (kg (lbs))

0.6

(1.32)

0.7

(1.54)

0.9

(1.98)

1.6

(3.52)

*1. The applicable motor capacity indicated is the maximum capacity applicable

when a Mitsubishi 4-pole standard motor is used.

*2. The rated output capacity indicated assumes that the output voltage is 230V.
*3. The % value of the overload capacity indicates the ratio of the overload current

to the inverter's rated output current.
For repeated duty, allow time for the inverter to return to or below the
temperatures under 100% load.

*4. For single-phase 100V power input, the output voltage provided cannot be

twice or more than the power supply voltage.

*5. The power supply capacity changes with the values of the power supply side

inverter impedances (including those of the input reactor and cables).

*6. For single-phase 100V power input, the application of motor load reduces the

output voltage about 10 to 15%. Therefore, the load must be reduced when a
general-purpose motor is used.

Advertising