MITSUBISHI ELECTRIC FR-S520 User Manual

Page 35

Advertising
background image

26

1) Sink logic type

In this logic, a signal switches on when a current flows out of the corresponding
signal input terminal.
Terminal SD is common to the contact input signals. Terminal SE is common to the
open collector output signals.

AX40

SE

RUN

24VDC

STR

STF

SD

R

1

9

R

R

R

A current flows out of
the corresponding
signal RUN

Inverter

Current

Connecting a positive external power supply
for transistor output to terminal PC prevents
a malfunction caused by a undesirable
current. (Do not connect terminal SD of the
inverter with terminal 0V of the external
power supply. When using terminals PC-SD
as a 24VDC power supply, do not install an
external power supply in parallel with the
inverter. Doing so may cause a malfunction
in the inverter due to a undesirable current.)

1

9

10

SD

PC

4

RM

3

RH

2

STR

STF

24VDC
(SD)

24VDC

5

RL

AY40 type
transistor
output module

Inverter