<Setting items and set data>

After completion of parameter settings, set the instruction codes and data then start
communication from the computer to allow various types of operation control and monitoring.

No.

Item

Instruction

Code

Description

Number

of Data

Digits

(Data

code

FF = 1)

Read

H7B

H0000: Communication operation
H0001: External operation

1

Operation
mode

Write

HFB

H0000: Communication operation
H0001: External operation

4 digits

Output
frequency
[speed]

H6F

H0000 to HFFFF:Output frequency (hexadecimal)
in 0.01Hz increments
[Speed (hexadecimal) in r/min when Pr. 37 = "0.1
to 999"]

4 digits
(6 digits)

Output
current

H70

H0000 to HFFFF: Output current (hexadecimal) in
0.01A increments

4 digits

H0000 to HFFFF: Two most recent alarm definitions
Alarm definition display example (instruction code
H74)

b15

b8b7

b0

0 0 1 1 0 0

0

0

0 0 0 0 0

0

1

1

Previous alarm

(H30)

Most recent alarm

(HA0)

Alarm data

Data

Description Data

Description

H00

No alarm

H40

FIN

H10

OC1

H60

OLT

H11

OC2

H80

GF

H12

OC3

H90

OHT

H20

OV1

HA0

OPT

H21

OV2

HB0

PE

H22

OV3

HB1

PUE

H30

THT

HB2

RET

H31

THM

HC0

CPU*

2

Moni

to

ri

ng

Alarm
definition

H74 to H75

* Error code may not be returned.

4 digits

3

Run command

HFA

b0 :
b1 : Forward
rotation (STF)
b2 : Reverse
rotation (STR)*
b3 : Low speed (RL)*
b4 : Middle speed (RM)*
b5 : High speed (RH)*
b6 :
b7 :

b7

0

0

0

0

0

0

0

1

b0

[For example 1]

[Example 1] H02 ... Forward
rotation
[Example 2] H00 ... Stop

* Function change can be made using Pr. 60 to

Pr. 63 (input terminal function selection).