MITSUBISHI ELECTRIC FR-S520 User Manual
Page 56
47
2
Func-
tion
Pa-
rame-
ter
Indica-
tion
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
<EC
version>
Refer
To:
Cus-
tomer
Setting
15
Jog frequency 0 to 120Hz
0.1Hz
5Hz
67
16
Jog
acceleration/
deceleration
time
0 to 999s
0.1s
0.5s
67
17
RUN key
rotation
direction
selection
0: Forward rotation,
1: Reverse rotation
1
0
67
19
Base frequency
voltage
0 to 500V, 888, - - -
(0 to 800V, 888, - - -
for the 400V class.)
1V
- - -
<888>
59
20
Acceleration/
deceleration
reference
frequency
1 to 120Hz
0.1Hz
60Hz
<50Hz>
62
21
Stall
prevention
function
selection
0 to 31, 100
1
0
68
22 *
Stall
prevention
operation level
0 to 200%
1%
150%
69
23
Stall
prevention
operation level
compensation
factor at
double speed
0 to 200%, - - -
1%
- - -
69
24 *
Multi-speed
setting
(speed 4)
0 to 120Hz, - - -
0.1Hz
- - -
61
25 *
Multi-speed
setting
(speed 5)
0 to 120Hz, - - -
0.1Hz
- - -
61
26 *
Multi-speed
setting
(speed 6)
0 to 120Hz, - - -
0.1Hz
- - -
61
27 *
Multi-speed
setting
(speed 7)
0 to 120Hz, - - -
0.1Hz
- - -
61
S
tanda
rd
op
e
ra
ti
o
n
fun
c
ti
o
n
s
28
Stall
prevention
operation
reduction
starting
frequency
0 to 120Hz
0.1Hz
60Hz
<50Hz>
69
Pammet
e
r Li
s
t