MITSUBISHI ELECTRIC FR-S520 User Manual

Page 56

Advertising
background image

47

2

Func-

tion

Pa-

rame-

ter

Indica-

tion

Name

Setting Range

Minimum

Setting

Increments

Factory

Setting

<EC

version>

Refer

To:

Cus-

tomer

Setting

15

Jog frequency 0 to 120Hz

0.1Hz

5Hz

67

16

Jog
acceleration/
deceleration
time

0 to 999s

0.1s

0.5s

67

17

RUN key
rotation
direction
selection

0: Forward rotation,
1: Reverse rotation

1

0

67

19

Base frequency
voltage

0 to 500V, 888, - - -
(0 to 800V, 888, - - -
for the 400V class.)

1V

- - -

<888>

59

20

Acceleration/
deceleration
reference
frequency

1 to 120Hz

0.1Hz

60Hz

<50Hz>

62

21

Stall
prevention
function
selection

0 to 31, 100

1

0

68

22 *

Stall
prevention
operation level

0 to 200%

1%

150%

69

23

Stall
prevention
operation level
compensation
factor at
double speed

0 to 200%, - - -

1%

- - -

69

24 *

Multi-speed
setting
(speed 4)

0 to 120Hz, - - -

0.1Hz

- - -

61

25 *

Multi-speed
setting
(speed 5)

0 to 120Hz, - - -

0.1Hz

- - -

61

26 *

Multi-speed
setting
(speed 6)

0 to 120Hz, - - -

0.1Hz

- - -

61

27 *

Multi-speed
setting
(speed 7)

0 to 120Hz, - - -

0.1Hz

- - -

61

S

tanda

rd

op

e

ra

ti

o

n

fun

c

ti

o

n

s

28

Stall
prevention
operation
reduction
starting
frequency

0 to 120Hz

0.1Hz

60Hz

<50Hz>

69

Pammet

e

r Li

s

t

Advertising